Mts Series 505G2 SilentFlo Hydraulic Power Unit Model Manuel d'utilisateur Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
Model 505G2.07/.11 SilentFlo™ HPU
64
High Pressure Filter Kit
3. Connect the elbow to the input of the filter assembly. Connect the straight
tube to the output of the filter assembly.
High Pressure Filter Components
4. Connect the elbow of the filter assembly to the high pressure port on the
manifold assembly.
5. Connect the high pressure hose between the filter assembly and the high
pressure output port.
6. Turn on the hydraulic pressure and check for leaks.
Replacing the Filter
Element
The high pressure filter should be changed every 1000 hours or six months, or
when the Dirty Filter indicator is lit. You will need a filter element (MTS part
number 100-030-007) or a filter kit (MTS part number 100-030-194).
To replace the filter:
1. Ensure that system hydraulic pressure has been reduced to zero before
proceeding. To do this, turn off the hydraulic power unit and exercise the
actuator until it stops moving.
2. Unscrew the filter bowl and remove the filter element.
3. Lift the filter element out of the filter bowl. Be careful to catch any
hydraulic fluid dripping from the filter element with a rag or drip pan.
4. Insert the replacement filter into the filter assembly.
High
Pressure
Port
Elbow
High
Pressure
Hose
High
Pressure
Output Port
Control Manifold
Filter
Assembly
Check Valve