Road and Track Vehicles
SWIFT 10 ATV Sensors Installing the Transducer
75
Note Some data acquisition systems may introduce electrical noise spikes to
the battery and cabling. The TI electronics should always be used with
the cleanest power supply possible. To reduce the likelihood of noise
spikes from the data recorder, we suggest running the power cables in
parallel, as shown in the following diagrams. If this does not remove the
noise spikes, separate batteries may be required.
The data recorder should also be connected to the battery negative terminal.
(See the following figures.)
Suggested Grounding for a single TI Box
Suggested Grounding for a Multiple TI Boxes
3. Secure the TI box so that it will not move during data collection.
Note If the TI box is not properly secured, it can dislodged from the ATV.
4. Cover the J4 I/O and J5 USB connectors to protect the connectors from
contamination.
12 Vdc
Transducer Interface
S10-25
Data Recorder
12 Vdc
Transducer Interface
Transducer Interface
Transducer Interface