Model 505G2.07/.11 SilentFlo™ HPU
18
Auto-Cooling Valve (adjustable)
Auto-Cooling Valve (adjustable)
The auto-cooling function is integrated into the control manifold. During periods
of low flow demand from the external hydraulic circuit, this feature provides two
important benefits: a re-circulating flow that ensures hydraulic fluid filtering
whenever the unit is on, and safeguarding against hydraulic fluid over-
temperature. It functions by opening a hydraulic flow path through the fluid
conditioning circuit when external hydraulic demand for flow is low. When the
external demand increases, this feature closes the path to provide the full flow of
the HPU to the external demand.
The effective operating range of the auto-cooling circuit is between system
pressures of 14 MPa (2000 psi) to 21 MPa (3000 psi). In order for the Auto-
Cooling Valve to function properly, it must be re-adjusted anytime the output
pressure will be changed for longer than 10 minutes.
Note If the test condition requires a maximum pressure level less than 14 MPa
(2000 psi), consult MTS.
Electrical Control
The HPU can be controlled locally using the front panel controls, or remotely
through a controller. A PLC (programmable logic controller) manages the
electrical systems within the HPU. The controls included in the electrical
enclosure include the following:
A user interface panel that contains a touch screen to program preferences
and operational settings. The screens on the user interface panel provide
quick indication of the unit’s condition, including motors status, running
time displays for each motor, hydraulic fluid level and temperature, and
filter condition.
Wye-delta starting reduces the initial current rush when the motor starters
are engaged.
Thermal overloads protect the individual HPU motors from excessive
current draw.
A latchable Emergency Stop button prevents inadvertent starts.
Interlocks protect the HPU against low hydraulic fluid level,
overtemperature, and dirty filters.
A Reset button brings the unit back into operation after a fault has been
detected and corrected.
A dirty filter signal will not shut the unit down, but will prevent the unit
from starting.
The power disconnect switch on the door of the main electrical enclosure
ensures that power is removed whenever the door is opened. This device is a
TÜV-certified, lockable, main-disconnect switch.